<div class="detailmodule_html"><div class="detail-desc-decorate-richtext"><br/></div></div><div class="detailmodule_dynamic"><kse:widget data-widget-type="customText" id="1005000000650092" type="relation"></kse:widget></div><div class="detailmodule_html"><div class="detail-desc-decorate-richtext"><div><strong><br/><br/>Features:</strong><br/><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">1.Small and compact product</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">2.With power indicator light</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">3.Service life: greater than 100000 times</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">4.Equipped with anti reverse connection protection, the reverse connection of the power supply will not burn the board</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">5.Capable of controlling equipment with AC voltage up to 220V10A or DC voltage up to 30V10A</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">6.Function Description</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">7.This module can detect the concentration of smoke, and can set one smoke detection threshold during use. When the smoke sensor detects that the ambient smoke concentration is greater than the set smoke threshold, the relay closes and the alarm indicator light lights up, and the buzzer sounds an alarm prompt. When the smoke sensor detects that the ambient smoke concentration drops below the set smoke threshold, the relay disconnects and the alarm indicator light goes out, and the buzzer stops alarming.</span></div><br/><p><strong><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">Description:<br/></span></strong><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">Working voltage: DC5-30V.</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">Output capacity: It can control devices within 220V10A AC or 30V10A DC.</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">Static current: 20mA,</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">Dynamic current: 50mA.</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">Equipped with anti reverse connection protection, the power supply reverse connection will not burn the board.</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">Service life: over 100000 times, working temperature: -40--85C</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">Board size: 49 * 45 * 20mm,</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">Positioning holes: with a spacing of 44mm in length and 40mm in width, and an aperture distance of 2 5mm, aperture 3mm.</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">[1] Alarm buzzer</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">[2] Status indicator light, indicator light on, buzzer alarm, and relay closed (9 and 10 closed, 10 and 11 disconnected). The indicator light goes out, the buzzer stops alarming, and the relay is disconnected (9 and 10 are disconnected, 10 and 11 are closed).</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">[3] Smoke detection sensor, try to keep the smoke sensor close to the smoke as much as possible for more accurate detection</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">[4] The smoke concentration detection setting knob is rotated clockwise to provide a smoke concentration threshold; Rotate counterclockwise to lower the smoke concentration threshold.</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">[5] Power indicator light, permanently on after power supply</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">[6] Negative pole of power supply</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">[7] Positive pole of power supply</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">[8] The working power supply rotates, and the DC 5-7V pins are plugged in with a short-circuit cap, while the DC 7-30V pins are disconnected</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">[9] Normally open pin of relay</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">[10] Relay common pin</span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">[11] Normally closed foot of relay</span></p><p><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif"><strong>Package include:</strong></span><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif"><br/></span><br/><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif">1 x sensor<br/></span><span style="color:rgb(0, 0, 0);font-size:16px;font-family:arial, helvetica, sans-serif"><br/></span></p></div></div><br/>