<div class="detailmodule_html"><div class="detail-desc-decorate-richtext"><h2 style="color:rgb(34, 34, 34);box-sizing:border-box"><strong><span style="font-size:16px">Specifications:</span></strong></h2><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Remote control Transmitter</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Operating voltage: DC12V (23A/12V battery x1)</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Transmitting frequency: 433MHz</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Encoding Type: Fixed code</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Receiver sensitivity: > -105dB</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Transmission distance : 100M (Open field)</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Size: approx 55*28*10mm</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Receiver board</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Operating voltage: AC 110V - 240V</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Output voltage = Operating voltage</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Operating frequency: 433MHz(Same with Remote control)</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Encoding Type: learning code(you can buy extra 315MHz remote controllers for this receiver)</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Rated contact current of relay: 15A/240VAC, 15A/110VAC (Please notice that : Although the relay is marked 30A 240VAC. The 30A is for the peak current of your load. The rated current of your load should less than 15A)</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Box size: approx 65 x 45 x 28mm</span></h3><h2 style="color:rgb(34, 34, 34);box-sizing:border-box"><strong><span style="font-size:16px">Instructions:</span></strong></h2><p style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">1. Jog: The remote control is controlled by a button. After pressing the button, the relay is closed, and when the button is released, the relay is disconnected.</span></p><p style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">2. Self-locking: The remote control is controlled by a button. Press the button once to pull in the relay, and press it again to disconnect.</span></p><p style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">3. Interlock: The remote control is controlled by two buttons. Press the A button to close the relay, and press the B button to disconnect.</span></p><p style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">4. Delay: After the pairing is successful, the relay will automatically disconnect after 5 seconds/10 seconds/15 seconds/20 seconds.</span></p><h2 style="color:rgb(34, 34, 34);box-sizing:border-box"><strong><span style="font-size:16px">Learn to code:</span></strong></h2><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">1. Jog learning method:</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Press the learning button of the controller once, the indicator light flashes quickly and it is in the learning state, and then press any button of the remote control you want to learn to send a code. At this time, the indicator light flashes three times and goes out, and the code matching is completed.</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">2. Self-locking learning method:</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Press the controller learning button twice, the indicator light flashes twice quickly in the learning state, and then press any button you want to learn on the remote control to send a code. At this time, the indicator light flashes three times and goes out, and the code matching is completed.</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">3. Interlocking learning method:</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Press the controller learning button three times, the indicator light flashes three times quickly in the learning state, at this time press the remote control A button, the indicator light flashes three times, and then press the remote control B button again, the indicator flashes three times and goes out, and the code matching is completed .</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">4. Learning method with a 5-second delay:</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Press the controller learning button four times, the indicator light flashes four times and then press the remote control to send a code, the receiver indicator flashes three times and then the learning is successful, then press the remote control to send the code, the relay will automatically disconnect after 5 seconds of closing.</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">5. Learning method with a 10-second delay:</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Press the controller learning button five times, the indicator light flashes five times and then press the remote control to send the code, the receiver indicator flashes three times and then the learning is successful, then press the remote control to send the code, and the relay will automatically disconnect after 10 seconds.</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">6. Learning method with 15 seconds delay:</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Press the controller learning button six times, the indicator light flashes six times and then press the remote control to send a code, the receiver indicator flashes three times and then the learning is successful, then press the remote control to send the code, and the relay will automatically disconnect after 15 seconds of closing.</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">7. Learning method with a delay of 20 seconds:</span></h3><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Press the controller learning button seven times, the indicator light flashes seven times and then press the remote control to send the code, the receiver indicator flashes three times and then the learning is successful, then press the remote control to send the code, and the relay will automatically turn off after being closed for 20 seconds.</span></h3><h2 style="color:rgb(34, 34, 34);box-sizing:border-box"><strong><span style="font-size:16px">Clear data:</span></strong></h2><h3 style="color:rgb(34, 34, 34);box-sizing:border-box"><span style="font-size:16px">Press and hold the learning button for 8 seconds without letting go, the indicator light flashes once until the receiver indicator flashes 6 times quickly, the code clearing is successful.</span></h3><div><br/><br/><br/><br/><br/><br/><br/><br/><br/></div></div></div><p><br/></p>