Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A
Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A
Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A
Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A
Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A
Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A
Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A
Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A
Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A
Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A
Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A
Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A

Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A

<div class="detailmodule_text"><p style="font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-title">Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A</p></div><div class="detailmodule_text"><p style="font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-title">Features</p><p style="font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-content">1.Detects all HFC (134a) CFC refrigerants.<br/>2.Sensitivity adjusted at any time and it can be adjusted automatically to the best state of detecting.<br/>3.Audible alarm and flashing light indicator upon gas leakage detected.<br/>4.Inner precise I C with ultra-low consume circuit design, more stable, longer battery time.<br/>5.Two color visual display of battery voltage.<br/>6.Excellent sensor, high sensitivity, longer use time.</p></div><div class="detailmodule_text"><p style="font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-title">Application:</p><p style="font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-content">It responds to ALL halogenated (containing chlorine or fluorine) refrigerants, including:<br/>CFCs – e.g. R11, R12, R500, R503 etc<br/>HCFCs – e.g. R22, R123, R124, R502<br/>HFCs – e.g. R125, R134a, R404a<br/>Blends including AZ-50, HP62, MP39 etc.<br/>Detect ethylene oxide gas leaks in hospital sterilizing equipment.<br/>Detect SF-6 in high voltage circuit breakers.<br/>Detect most gasses that contain chlorine, fluorine and bromine (halogen gasses).<br/>Detects cleaning agents used when dry cleaning such as perchloroethy.<br/>Detects halogen gasses in fire extinguishing systems.</p></div><div class="detailmodule_text"><p style="font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-title">Parameters:</p><p style="font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-content">Operating temperature:0°C to 52°C (30°F t 125°F)<br/>Maximum sensitivity: 6gr/yr for all halogenated refrigerants<br/>Battery life: approximately 50 hours normal use<br/>Response time: immediate<br/>Work mode: continuous – no limitations<br/>Fixed probe length: 20cm<br/>Unit dimensions: 15 x3 x 3 cm<br/>Warm-up time: approximately 6 seconds<br/>Reset time: 2 to 10 seconds<br/>Powered by: 2 x AAA 1.5V batteries (not included)</p></div><div class="detailmodule_image"></div><div class="detailmodule_image"></div><p><br/></p>
$76.865
$33.44

Colors

Sizes

-
+
<div class="detailmodule_text"><p style="font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-title">Halogen Leak Detector Freon Gas Analyzer CFC HFC HVAC Halogen Refrigerant Gas Detector Air Conditioning Tester R22 R410A R134A</p></div><div class="detailmodule_text"><p style="font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-title">Features</p><p style="font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-content">1.Detects all HFC (134a) CFC refrigerants.<br/>2.Sensitivity adjusted at any time and it can be adjusted automatically to the best state of detecting.<br/>3.Audible alarm and flashing light indicator upon gas leakage detected.<br/>4.Inner precise I C with ultra-low consume circuit design, more stable, longer battery time.<br/>5.Two color visual display of battery voltage.<br/>6.Excellent sensor, high sensitivity, longer use time.</p></div><div class="detailmodule_text"><p style="font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-title">Application:</p><p style="font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-content">It responds to ALL halogenated (containing chlorine or fluorine) refrigerants, including:<br/>CFCs – e.g. R11, R12, R500, R503 etc<br/>HCFCs – e.g. R22, R123, R124, R502<br/>HFCs – e.g. R125, R134a, R404a<br/>Blends including AZ-50, HP62, MP39 etc.<br/>Detect ethylene oxide gas leaks in hospital sterilizing equipment.<br/>Detect SF-6 in high voltage circuit breakers.<br/>Detect most gasses that contain chlorine, fluorine and bromine (halogen gasses).<br/>Detects cleaning agents used when dry cleaning such as perchloroethy.<br/>Detects halogen gasses in fire extinguishing systems.</p></div><div class="detailmodule_text"><p style="font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-title">Parameters:</p><p style="font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px" class="detail-desc-decorate-content">Operating temperature:0°C to 52°C (30°F t 125°F)<br/>Maximum sensitivity: 6gr/yr for all halogenated refrigerants<br/>Battery life: approximately 50 hours normal use<br/>Response time: immediate<br/>Work mode: continuous – no limitations<br/>Fixed probe length: 20cm<br/>Unit dimensions: 15 x3 x 3 cm<br/>Warm-up time: approximately 6 seconds<br/>Reset time: 2 to 10 seconds<br/>Powered by: 2 x AAA 1.5V batteries (not included)</p></div><div class="detailmodule_image"></div><div class="detailmodule_image"></div><p><br/></p>