Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter
Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter
Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter
Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter
Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter
Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter
Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter
Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter
Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter
Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter
Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter
Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter

Phase Rotation Monitor Phase Sequence Meter AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter

<div class="detailmodule_html"><div class="detail-desc-decorate-richtext"><div> <kse:widget data-widget-type="customText" id="1005000011722001" type="custom"></kse:widget> </div><div class="desc"> <p><br /></p> <p>AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter</p> <p><strong>Specification:</strong></p> <p>Feature:<br />Phase sequence detection, live line check, simple power check, live wire identification, phase loss judgment, wire break position search, DC line break point detection, line maintenance.&nbsp;<br />Clamp-type non-contact inductive measurement, no need to open the wire, no need to touch the high-voltage exposed fire wire, directly sandwich the three super-inductive high-insulation clamps to the insulation skin of the three-phase live wire to detect the phase sequence.&nbsp;<br />Non-contact inspection for safe and fast productivity.&nbsp;<br />The dynamic sound and light indicates the positive or negative phase of the phase sequence of the three-phase power supply, which is clear at a glance.&nbsp;<br />The bottom plate of the instrument is equipped with 4 magnets, which can be attached to the metal casing of the equipment during testing, and the operation is convenient and convenient.<br />Specification:<br />Model ETCR1000C&nbsp;<br />Functions Phase detection (Positive&nbsp;phase, reverse phase and phaseloss), Live wire examination, Simple Power detection, Breakpoint location and Line maintenance. &nbsp;&nbsp;<br />Power Supply DC&nbsp;3V2*AA Alkaline dry battery , Continuously working for&nbsp;70&nbsp;hours&nbsp;<br />AC Voltage Range(V) AC&nbsp;70&nbsp;- 1000V, 40/65Hz (Sine Wave Continuous Input)&nbsp;<br />Clamp Wire Size External Diameter 1.6-16mm&nbsp;<br />LED Display (Positive Phase Sequence) The four phase-sequence lamps light&nbsp;in order (clockwise). (Negative Phase Sequence) The four phase-sequence lamps light&nbsp;in order (counterclockwise). (Live Power)L1,L2,L3&nbsp;lamp light up&nbsp;in the voltage setting range. (Phase&nbsp;Loss) L1 or L2 or L3 does not light. (Short&nbsp;Circuit)L1 or L2 or L3 does not light.&nbsp;<br />Buzzing (Positive phase) The instrument emits intermittent short beeps; (Reverse phase) The instrument emits a continuous long beep.&nbsp;<br />Power On Indication Power on indication light turns on; Low power, low battery light on&nbsp;<br />Magnetic force Four magnets on the back of the meter, which are attached to the distribution box and can withstand 800g quality.&nbsp;<br />Auto Power off After&nbsp;5 minutes, the meter automatically cut off power supply.&nbsp;<br />Meter Dimension Width, height, thickness 70mm*75mm*30mm&nbsp;<br />Clamp Lead Length 0.6m&nbsp;<br />Weight 317g&nbsp;<br />Working Temperature and Humidity -10℃-55℃; below 80%rh&nbsp;<br />Storage Temperature and Humidity -20℃-60℃; below 90%rh&nbsp;<br />Maximum Measured Voltage AC&nbsp;1000V&nbsp;<br />Dielectric Strength 5.4kVrms&nbsp;<br />Maximum rated Power 100mVA&nbsp;<br />Safety Provisions EN61010-1: 2001, EN61010-031: 2002, Pollution level 2, CAT 3 (600V), Transient over-voltage 6000V<br /></p> <p></p> <p>Package list:<br />1 * Non-Contact Phase Sequence Detector<br />1 * User Manual<br />Note:<br />The actual product color may deviate from the photo due to light.<br />There may be a slight deviation in the measurement of product.<br /><br /></p> <p></p> <p><br /></p> </div><div> <kse:widget data-widget-type="customText" id="1005000012558401" type="custom"></kse:widget> </div><br /></div></div>
$123.035
$68.57

Colors

Sizes

-
+
<div class="detailmodule_html"><div class="detail-desc-decorate-richtext"><div> <kse:widget data-widget-type="customText" id="1005000011722001" type="custom"></kse:widget> </div><div class="desc"> <p><br /></p> <p>AC 70-1000V ETCR1000C Non Contact Phase Sequence Detector Magnetic Base Phase Meter</p> <p><strong>Specification:</strong></p> <p>Feature:<br />Phase sequence detection, live line check, simple power check, live wire identification, phase loss judgment, wire break position search, DC line break point detection, line maintenance.&nbsp;<br />Clamp-type non-contact inductive measurement, no need to open the wire, no need to touch the high-voltage exposed fire wire, directly sandwich the three super-inductive high-insulation clamps to the insulation skin of the three-phase live wire to detect the phase sequence.&nbsp;<br />Non-contact inspection for safe and fast productivity.&nbsp;<br />The dynamic sound and light indicates the positive or negative phase of the phase sequence of the three-phase power supply, which is clear at a glance.&nbsp;<br />The bottom plate of the instrument is equipped with 4 magnets, which can be attached to the metal casing of the equipment during testing, and the operation is convenient and convenient.<br />Specification:<br />Model ETCR1000C&nbsp;<br />Functions Phase detection (Positive&nbsp;phase, reverse phase and phaseloss), Live wire examination, Simple Power detection, Breakpoint location and Line maintenance. &nbsp;&nbsp;<br />Power Supply DC&nbsp;3V2*AA Alkaline dry battery , Continuously working for&nbsp;70&nbsp;hours&nbsp;<br />AC Voltage Range(V) AC&nbsp;70&nbsp;- 1000V, 40/65Hz (Sine Wave Continuous Input)&nbsp;<br />Clamp Wire Size External Diameter 1.6-16mm&nbsp;<br />LED Display (Positive Phase Sequence) The four phase-sequence lamps light&nbsp;in order (clockwise). (Negative Phase Sequence) The four phase-sequence lamps light&nbsp;in order (counterclockwise). (Live Power)L1,L2,L3&nbsp;lamp light up&nbsp;in the voltage setting range. (Phase&nbsp;Loss) L1 or L2 or L3 does not light. (Short&nbsp;Circuit)L1 or L2 or L3 does not light.&nbsp;<br />Buzzing (Positive phase) The instrument emits intermittent short beeps; (Reverse phase) The instrument emits a continuous long beep.&nbsp;<br />Power On Indication Power on indication light turns on; Low power, low battery light on&nbsp;<br />Magnetic force Four magnets on the back of the meter, which are attached to the distribution box and can withstand 800g quality.&nbsp;<br />Auto Power off After&nbsp;5 minutes, the meter automatically cut off power supply.&nbsp;<br />Meter Dimension Width, height, thickness 70mm*75mm*30mm&nbsp;<br />Clamp Lead Length 0.6m&nbsp;<br />Weight 317g&nbsp;<br />Working Temperature and Humidity -10℃-55℃; below 80%rh&nbsp;<br />Storage Temperature and Humidity -20℃-60℃; below 90%rh&nbsp;<br />Maximum Measured Voltage AC&nbsp;1000V&nbsp;<br />Dielectric Strength 5.4kVrms&nbsp;<br />Maximum rated Power 100mVA&nbsp;<br />Safety Provisions EN61010-1: 2001, EN61010-031: 2002, Pollution level 2, CAT 3 (600V), Transient over-voltage 6000V<br /></p> <p></p> <p>Package list:<br />1 * Non-Contact Phase Sequence Detector<br />1 * User Manual<br />Note:<br />The actual product color may deviate from the photo due to light.<br />There may be a slight deviation in the measurement of product.<br /><br /></p> <p></p> <p><br /></p> </div><div> <kse:widget data-widget-type="customText" id="1005000012558401" type="custom"></kse:widget> </div><br /></div></div>

Related Product

Browse The Collection of Top Products.