• Blogs
  • Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination
    Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination
    Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination
    Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination
    Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination
    Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination
    Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination
    Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination
    Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination
    Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination
    Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination
    Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination

    Woods Lamp Skin Analyzer Portable Facial Salon Beauty Analyzer UV Lamp Wood Dermatology for Analyzing Testing Examination

    <div class="detailmodule_html"><div class="detail-desc-decorate-richtext"><p style="text-align:center" align="center"><strong><span style="font-size:26px"><span style="font-family:Arial, Helvetica, sans-serif">Woods Lamp Skin Analyzer for Skin Testing Home Use Salon SPA Machine Facial Skin Scanner UV Magnifying Analyzer</span></span></strong></p><p style="margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;display:block;width:100%"></p><div><br/></div><div style="position:relative"><div style="position:relative"><strong><span class="null hover-sent"><span>1.1 Important tips and safety protection</span></span></strong></div><div style="position:relative"><span class="null"><span>Thank you for purchasing this product. Please read the instructions carefully to ensure continuous and safe use of the instrument. You must follow the listed instructions for use. Wood&#x27;s lamp uses a professional ultraviolet lamp chip for detection. This lamp chip can emit modulated long-wave ultraviolet light and can penetrate into the middle dermis of the skin. </span></span> <span>After epidermal melanin and dermal collagen absorb ultraviolet light of a certain wavelength,blue and other fluorescence can be found when observed in a glass mirror. The state of this fluorescence mainly depends on the conditions of the skin epidermis and skin dermis. If the health of the skin is different, the fluorescence produced will also change. The skin condition cannot be confirmed with the naked eye, but the Wood lamp can be used to obtain detailedconditions. Through the lens, the skin condition and problems of the exa miner can be easily identified.We are not responsible for personal or instrument damage caused by abnormal operation or operation.</span></div><div style="position:relative"><strong><span>1.2 Matters need attention</span></strong></div><div style="position:relative"><span>1.To prevent electric shock and reduce instrument failure,the instrument must not be immersed in water. If the instrument accidentally enters water, please stop using it immediately and hand it over to a professional for repair before use.</span></div><div style="position:relative"><span>2.The safety of the connecting cables should be carefuly observed before the instrument is put into use, and damaged cables and connectors should be handled in time.</span></div><div style="position:relative"><span> 3.Gradually reduce or increase the irradiation dose according to the increase or decrease of the patient&#x27;s erythema.</span></div><div style="position:relative"><span> 4.To ensure the safe operation of the instrument, all kinds of replaceable parts, accessories and consumables of the instrument should use our company&#x27;s products and be specified by the company.</span></div><div style="position:relative"><span>5.Handling of accessories and instruments Packaging materials should be handled in accordance with relevant local waste disposal regulations to prevent children from contact.If problems occur during use, relevant operations can be performed by filling in the product warranty card.</span></div><div style="position:relative"><span>6.0perating instructions To ensure the continued safe use of this instrument, the listed usage methods must be followed. However, these usage guidelines shall not replace recognized experience in medical practice regarding patient care.</span></div><div style="position:relative"><div><span>7.The device does not work while charging.<br/></span><span><strong>1.3 Important Note</strong></span></div><div style="position:relative"><span>1.Please refer to the relevant documents of this instrument.</span></div><div style="position:relative"><span> 2.Do not look directly at the U-v light source for a long time. The patient must close his eyes during the facial examination. The instrument should be kept at a distance of 5-6 cm from the skin surface of the tester.</span></div><div style="position:relative"><span>3.Please use this irradiator in a clean and dry environment and place it!</span></div><div style="position:relative"><span>4.Avoid operating next to equipment with strong electromagnetic interference! If you must use it close to it, you should observe and verify whether it is effective!</span></div><div style="position:relative"><span> 5.Children should use it under adult supervision.</span></div><div style="position:relative"><span>6.This equipment should be tested, maintained and safety checked by professionals!</span></div><div style="position:relative"><span> 7.The Woods lamp is a device for users to identify the skin condition and problem conditions of the tester!</span></div><div style="position:relative"><span> 8.Personal injury and property damage may occur when used improperly!</span></div><div style="position:relative"><span> 9.lf there is any danger, please stop using the disconnected power cord immediately and contact the manufacturer!</span></div><div style="position:relative"><span>10.lt is not recommended to work while charging the device, otherwise it will damage the life of the device.</span></div><div style="position:relative"><strong><span>1.4 Scope of application</span></strong></div><div style="position:relative"><span>The Woods lamp isa toolthat uses LED to radiate a specific wavelength of 365nm to observe the condition of the skin, increase the operator&#x27;s viewing angle, and facilitate observation of skin details.</span></div><div style="position:relative"><strong><span>1.5 Contraindications</span></strong></div><div style="position:relative"><div><span> Do not use this product in patients with excessive light sensitivity.</span></div><div style="position:relative"><span style="font-size:18px"><strong><span>Product parameter</span></strong></span></div><div style="position:relative"><span>Product Name:Portable Woods Lamp</span></div><div style="position:relative"><span>Product Material:A BS+pc</span></div><div style="position:relative"><span>Power Output:5w</span></div><div style="position:relative"><strong><span>Packing List</span></strong></div><div style="position:relative"><span>Handheld host x1 </span></div><div style="position:relative"><span>Charging Cable X1 </span></div><div style="position:relative"><span>Instruction manual x1 </span></div><div style="position:relative"><div><span>Li-ion lithium ion rechargeable battery</span></div><p style="text-align:left;margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px" align="left"></p><div style="position:relative"><span style="font-size:18px"><strong><span>Operation and Working principle</span></strong></span></div><div style="position:relative"><strong><span>3.1 Instructions on operation</span></strong></div><div style="position:relative"><span>1.Cleaning cover and lens: when cleaning, please ensure that the detergent used will not </span></div><div style="position:relative"><span>damage the glass and outer shell, to ensulre the maximum luminosity output.</span></div><div style="position:relative"><span>2.Before use, the skin cleaner is applied to clean the oil and dirt on the skin surface, which </span></div><div style="position:relative"><span>can clearly observe the dermal state ofthe skin to a large extent.</span></div><div style="position:relative"><span>3.Hold the wood light and press the switch, the LED light source will light up,then check.</span></div><div style="position:relative"><span>4.when using the protable wood lamp, itis most appropriate to keep the instrument at a distance of 5 - 6 cm from the skin surface.</span></div><div style="position:relative"><span>5.Test through a magnifying glass in a dark room.</span></div><div style="position:relative"><span>Note:</span></div><div style="position:relative"><span>The equipment before the factorythrough a strict qualityinspection,if found in the use ofabnormal work, please contact the company in time during the warranty period.</span></div><div style="position:relative"><span>If you have any problems with the instrument or have any ulestions about its operation, please read this instruction manual carefully. warranty period.</span></div><div style="position:relative"><strong><span>Principle of operation</span></strong></div><div style="position:relative"><div><span>electrical source—controller- LED light source</span><br/></div><div style="position:relative"><strong><span style="font-size:18px"><span>Maintenance and cleaning</span></span></strong></div><div style="position:relative"><span>In order to ensure the normal operation of the instrument and extend the service life of the instrument, attention should be paid to the maintenance and cleaning of the instrument.</span></div><div style="position:relative"><strong><span>4.1 Maintenance of instruments and accessories</span></strong></div><div style="position:relative"><span>4.1.1 In order to ensure the normal and safe work of the instrument, a preventive inspection (including performance inspection and safety inspection) and maintenance of the instrument and its accessories shall be conducted every 6 months, to prove that the instrument can work normally and is in good working conditions, which is safe for medical personnel and patients and achieves the accuracy required for clinical use.</span></div><div style="position:relative"><span>4.1.2 Pay attention to the voltage fuctuation of the local power grid. If it exceeds the allowable range, it is recommended to add voltage stabilization equipment.</span></div><div style="position:relative"><span>4.1.3 The instrument shell should not be opened without permission, so as to avoid undue failure and affect the normal use.</span></div><div style="position:relative"><span>4.1.4 The accessories of the instrument should be gently put, do not fall, touch, pull, can not be wiped with corrosive chemicals !</span></div><div style="position:relative"><span>4.1.5 When the service life of the instruments and accessories expires, they shall be treated accordingly in accordance with the relevant regulations on the treatment of electronic product waste issued.</span></div><div style="position:relative"><strong><span>4.2 Cleaning of instruments</span></strong></div><div style="position:relative"><span>Warning: Turn off the power and cut the AC power before cleaning the instrument.</span></div><div style="position:relative"><span>4.2.1 Avoid using ethanol, amino or acetone cleaners.</span></div><div style="position:relative"><span>4.2.2 The shell, mirror body and light source ofthe instrument shall be protected from dust, and can be wiped with wireless soft cloth or sponge infiltrated with detergent.</span></div><div><strong>4.3 Storage</strong><br/>If the instrument is not used for a long time, it should be wiped clean and put in the<br/>packaging box. The storage environment should be kept dry and ventilated.<br/><span style="font-size:18px"><strong>Woods lamp displays colored light to report skin condition</strong></span> <br/></div></div></div><p style="text-align:left;margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px" align="left"><br/><strong>Note:</strong> The fluorescence of hypopigmented or depigmented lesions such as vitiligo and pityriasis alba is easier to distinguish from normal skin color. Topical medications such as vaseline, salicylic acid, iodine tincture, keratin and even soap residues also have fluorescence, so you should pay attention to identification.<br/><br/><span style="font-size:18px"><strong>After-sales warranty service</strong></span><br/>1. Our company provides warranty for our products. If you need warranty, please fill in the basic information before returning to the factory for repair, so that our factory can repair and return it.<br/>2. Our company does not provide free warranty service for failures caused by the following<br/>reasons:<br/>1) Any careless or wrong use and damage caused by human factors.<br/><br/>2) Failure caused by improper repair and private modification by maintenance personnel not <br/>authorized by our company.<br/>3) All damage and failure caused by force majeure and natural disasters, such as fire,<br/>earthquake and other natural causes.<br/></p></div></div></div></div></div><p><br/></p>
    $87.65
    $44.825

    Colors

    Sizes

    -
    +
    <div class="detailmodule_html"><div class="detail-desc-decorate-richtext"><p style="text-align:center" align="center"><strong><span style="font-size:26px"><span style="font-family:Arial, Helvetica, sans-serif">Woods Lamp Skin Analyzer for Skin Testing Home Use Salon SPA Machine Facial Skin Scanner UV Magnifying Analyzer</span></span></strong></p><p style="margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;display:block;width:100%"></p><div><br/></div><div style="position:relative"><div style="position:relative"><strong><span class="null hover-sent"><span>1.1 Important tips and safety protection</span></span></strong></div><div style="position:relative"><span class="null"><span>Thank you for purchasing this product. Please read the instructions carefully to ensure continuous and safe use of the instrument. You must follow the listed instructions for use. Wood&#x27;s lamp uses a professional ultraviolet lamp chip for detection. This lamp chip can emit modulated long-wave ultraviolet light and can penetrate into the middle dermis of the skin. </span></span> <span>After epidermal melanin and dermal collagen absorb ultraviolet light of a certain wavelength,blue and other fluorescence can be found when observed in a glass mirror. The state of this fluorescence mainly depends on the conditions of the skin epidermis and skin dermis. If the health of the skin is different, the fluorescence produced will also change. The skin condition cannot be confirmed with the naked eye, but the Wood lamp can be used to obtain detailedconditions. Through the lens, the skin condition and problems of the exa miner can be easily identified.We are not responsible for personal or instrument damage caused by abnormal operation or operation.</span></div><div style="position:relative"><strong><span>1.2 Matters need attention</span></strong></div><div style="position:relative"><span>1.To prevent electric shock and reduce instrument failure,the instrument must not be immersed in water. If the instrument accidentally enters water, please stop using it immediately and hand it over to a professional for repair before use.</span></div><div style="position:relative"><span>2.The safety of the connecting cables should be carefuly observed before the instrument is put into use, and damaged cables and connectors should be handled in time.</span></div><div style="position:relative"><span> 3.Gradually reduce or increase the irradiation dose according to the increase or decrease of the patient&#x27;s erythema.</span></div><div style="position:relative"><span> 4.To ensure the safe operation of the instrument, all kinds of replaceable parts, accessories and consumables of the instrument should use our company&#x27;s products and be specified by the company.</span></div><div style="position:relative"><span>5.Handling of accessories and instruments Packaging materials should be handled in accordance with relevant local waste disposal regulations to prevent children from contact.If problems occur during use, relevant operations can be performed by filling in the product warranty card.</span></div><div style="position:relative"><span>6.0perating instructions To ensure the continued safe use of this instrument, the listed usage methods must be followed. However, these usage guidelines shall not replace recognized experience in medical practice regarding patient care.</span></div><div style="position:relative"><div><span>7.The device does not work while charging.<br/></span><span><strong>1.3 Important Note</strong></span></div><div style="position:relative"><span>1.Please refer to the relevant documents of this instrument.</span></div><div style="position:relative"><span> 2.Do not look directly at the U-v light source for a long time. The patient must close his eyes during the facial examination. The instrument should be kept at a distance of 5-6 cm from the skin surface of the tester.</span></div><div style="position:relative"><span>3.Please use this irradiator in a clean and dry environment and place it!</span></div><div style="position:relative"><span>4.Avoid operating next to equipment with strong electromagnetic interference! If you must use it close to it, you should observe and verify whether it is effective!</span></div><div style="position:relative"><span> 5.Children should use it under adult supervision.</span></div><div style="position:relative"><span>6.This equipment should be tested, maintained and safety checked by professionals!</span></div><div style="position:relative"><span> 7.The Woods lamp is a device for users to identify the skin condition and problem conditions of the tester!</span></div><div style="position:relative"><span> 8.Personal injury and property damage may occur when used improperly!</span></div><div style="position:relative"><span> 9.lf there is any danger, please stop using the disconnected power cord immediately and contact the manufacturer!</span></div><div style="position:relative"><span>10.lt is not recommended to work while charging the device, otherwise it will damage the life of the device.</span></div><div style="position:relative"><strong><span>1.4 Scope of application</span></strong></div><div style="position:relative"><span>The Woods lamp isa toolthat uses LED to radiate a specific wavelength of 365nm to observe the condition of the skin, increase the operator&#x27;s viewing angle, and facilitate observation of skin details.</span></div><div style="position:relative"><strong><span>1.5 Contraindications</span></strong></div><div style="position:relative"><div><span> Do not use this product in patients with excessive light sensitivity.</span></div><div style="position:relative"><span style="font-size:18px"><strong><span>Product parameter</span></strong></span></div><div style="position:relative"><span>Product Name:Portable Woods Lamp</span></div><div style="position:relative"><span>Product Material:A BS+pc</span></div><div style="position:relative"><span>Power Output:5w</span></div><div style="position:relative"><strong><span>Packing List</span></strong></div><div style="position:relative"><span>Handheld host x1 </span></div><div style="position:relative"><span>Charging Cable X1 </span></div><div style="position:relative"><span>Instruction manual x1 </span></div><div style="position:relative"><div><span>Li-ion lithium ion rechargeable battery</span></div><p style="text-align:left;margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px" align="left"></p><div style="position:relative"><span style="font-size:18px"><strong><span>Operation and Working principle</span></strong></span></div><div style="position:relative"><strong><span>3.1 Instructions on operation</span></strong></div><div style="position:relative"><span>1.Cleaning cover and lens: when cleaning, please ensure that the detergent used will not </span></div><div style="position:relative"><span>damage the glass and outer shell, to ensulre the maximum luminosity output.</span></div><div style="position:relative"><span>2.Before use, the skin cleaner is applied to clean the oil and dirt on the skin surface, which </span></div><div style="position:relative"><span>can clearly observe the dermal state ofthe skin to a large extent.</span></div><div style="position:relative"><span>3.Hold the wood light and press the switch, the LED light source will light up,then check.</span></div><div style="position:relative"><span>4.when using the protable wood lamp, itis most appropriate to keep the instrument at a distance of 5 - 6 cm from the skin surface.</span></div><div style="position:relative"><span>5.Test through a magnifying glass in a dark room.</span></div><div style="position:relative"><span>Note:</span></div><div style="position:relative"><span>The equipment before the factorythrough a strict qualityinspection,if found in the use ofabnormal work, please contact the company in time during the warranty period.</span></div><div style="position:relative"><span>If you have any problems with the instrument or have any ulestions about its operation, please read this instruction manual carefully. warranty period.</span></div><div style="position:relative"><strong><span>Principle of operation</span></strong></div><div style="position:relative"><div><span>electrical source—controller- LED light source</span><br/></div><div style="position:relative"><strong><span style="font-size:18px"><span>Maintenance and cleaning</span></span></strong></div><div style="position:relative"><span>In order to ensure the normal operation of the instrument and extend the service life of the instrument, attention should be paid to the maintenance and cleaning of the instrument.</span></div><div style="position:relative"><strong><span>4.1 Maintenance of instruments and accessories</span></strong></div><div style="position:relative"><span>4.1.1 In order to ensure the normal and safe work of the instrument, a preventive inspection (including performance inspection and safety inspection) and maintenance of the instrument and its accessories shall be conducted every 6 months, to prove that the instrument can work normally and is in good working conditions, which is safe for medical personnel and patients and achieves the accuracy required for clinical use.</span></div><div style="position:relative"><span>4.1.2 Pay attention to the voltage fuctuation of the local power grid. If it exceeds the allowable range, it is recommended to add voltage stabilization equipment.</span></div><div style="position:relative"><span>4.1.3 The instrument shell should not be opened without permission, so as to avoid undue failure and affect the normal use.</span></div><div style="position:relative"><span>4.1.4 The accessories of the instrument should be gently put, do not fall, touch, pull, can not be wiped with corrosive chemicals !</span></div><div style="position:relative"><span>4.1.5 When the service life of the instruments and accessories expires, they shall be treated accordingly in accordance with the relevant regulations on the treatment of electronic product waste issued.</span></div><div style="position:relative"><strong><span>4.2 Cleaning of instruments</span></strong></div><div style="position:relative"><span>Warning: Turn off the power and cut the AC power before cleaning the instrument.</span></div><div style="position:relative"><span>4.2.1 Avoid using ethanol, amino or acetone cleaners.</span></div><div style="position:relative"><span>4.2.2 The shell, mirror body and light source ofthe instrument shall be protected from dust, and can be wiped with wireless soft cloth or sponge infiltrated with detergent.</span></div><div><strong>4.3 Storage</strong><br/>If the instrument is not used for a long time, it should be wiped clean and put in the<br/>packaging box. The storage environment should be kept dry and ventilated.<br/><span style="font-size:18px"><strong>Woods lamp displays colored light to report skin condition</strong></span> <br/></div></div></div><p style="text-align:left;margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px" align="left"><br/><strong>Note:</strong> The fluorescence of hypopigmented or depigmented lesions such as vitiligo and pityriasis alba is easier to distinguish from normal skin color. Topical medications such as vaseline, salicylic acid, iodine tincture, keratin and even soap residues also have fluorescence, so you should pay attention to identification.<br/><br/><span style="font-size:18px"><strong>After-sales warranty service</strong></span><br/>1. Our company provides warranty for our products. If you need warranty, please fill in the basic information before returning to the factory for repair, so that our factory can repair and return it.<br/>2. Our company does not provide free warranty service for failures caused by the following<br/>reasons:<br/>1) Any careless or wrong use and damage caused by human factors.<br/><br/>2) Failure caused by improper repair and private modification by maintenance personnel not <br/>authorized by our company.<br/>3) All damage and failure caused by force majeure and natural disasters, such as fire,<br/>earthquake and other natural causes.<br/></p></div></div></div></div></div><p><br/></p>